Promo Flue & Combustion Gas Analyzer


more info : bahtiar@gmail.com

Key : kimo instruments analyser detector monitor KIGAZ 210 long life O2 sensor interchangeable CO H2 NO CH4 CO solenoid valve auto zeroing flue built in printer intuitive interface due to icons led on the probe handle to light dark areas single connector interchangeable probe  2 go memory 100 000 measurements step by step procedure menu gas flow inspections conformity the analyser is in compliance with the following european directives 2004/108/EC 2006/95/EC low voltage 2011/65/EU RoHS II 2012/19/EU WEEE Standards EN 50379-1 EN 50379-2 standards gas autozero in the flue CO sensor protection by solenoid valve flue gas CO and ambient max CO interchangeable sensors long-life O2 and CO-H2 and NO and CH4 excess air losses efficiency 100% PRESSURE Differential pressure measurement Draft measurement TEMPERATURE Ambient temperature Flue gas temperature Delta Temperature DHW temperature 2 thermocouples Dew point temperature 5 programmed combustibles Adding  combustibles by the user Opacity index COMBUSTION GAS ANALYSER Interchangeable CO-H2 NO and CH4 sensors CO sensor protection by solenoid valve Long-life O2 sensor Combustibles Sahara/Fos-sur-Mer Natural Gas Groningen Natural Gas Russia/North Sea Natural Gas Propane LPG Butane Light Oil Heavy Oil Bituminous coal Hard coal  Coke gas Bio fuel 5 % Wood 20 % Wood-chip 21 % Pellet 8 % Parameter Sensor Measuring range Resolution Accuracy T90 response time Long-life O2 Electro-chemical From 0 % to 21 % 0.1 % vol. ±0.2 % vol. 30 s CO (with H2 compensation) Electro-chemical From 0 to 8000 ppm 1 ppm From 0 to 200 ppm: ±10 ppm From 201 to 2000 ppm: ±5% of measured value From 2001 to 8000 ppm: ±10% of measured value 30 s NO Electro-chemical From 0 to 5000 ppm 1 ppm From 0 to 100 ppm: ±5 ppm From 101 to 5000 ppm: ±5% of measured value 30 s Low range NO Electrochemical From 0 to 500 ppm 0.1 ppm From 0 to 100 ppm: ±2 ppm From 101 to 500 ppm: ±2 % of the measured value 30 s NOx Calculated** From 0 to 5155 ppm 1 ppm - - CO2 Calculated** From 0 to 99 % vol 0.1 % vol - - CH4 Semiconductor From 0 to 10000 ppm From 0 to 1 % Vol From 0 to 20 %LEL 1 ppm 0.0001 % Vol 0.002 %LEL ±20 % of full scale 40 s Flue gas temperature K thermocouple From -100 to +1250 °C 0.1 °C ±0.4 % of measured value or ±1.1 °C 45 s Ambient temperature Internal NTC From -20 to +120 °C 0.1 °C ±0.5 °C Ambient temperature Pt100 (1/3 DIN external probe) From -50 to +250 °C 0.1 °C ±0.3 % of measured value ±0.25 °C 30 s Dew point temperature Calculated** From 0 to +99 °Ctd 0.1 °C - -DHW temperature TcK (external probe) From -200 to +1300 °C 0.1 °C ±0.4 % of measured value or ±1.1 °C - Differential pressure Piezoelectric From -20 000 to +20 000 Pa 1 Pa From -20 000 to -751 Pa: ±0.5 % of measured value ±4.5 Pa From 750 to -61 Pa: ±0.9% of measured value ±1.5 Pa From -60 to 60 Pa: ±2 Pa From 61 to 750 Pa: ±0.9% of measured value ±1.5 Pa From 751 to 20 000 Pa: ±0.5% of measured value ±4.5 Pa Draft From -10 to +10 Pa From -1000 to +1000 Pa 0.1 Pa 1 Pa Losses Calculated** From 0 to 100% 0.1% - - Flue gas velocity Calculated** From 0 to 99.9 m/s 0.1 m/s - - Excess air (λ) Calculated** From 1 to 9.99 0.01 - - Efficiency (ηs) Calculated** From 0 to 100 % 0.1 % - - Efficiency (ηt) (condensation) Calculated** From 0 to 120 % 0.1 % - - Opacity index External instrument From 0 to 9 Dimensions Instrument: 331 x 112 x 86 mm; Flue gas: 300 mm ; Cable length: 2.50 m Weight (with battery and protective cover included) 1060 g Display LCD 120 x 160 pixels, 50 x 67 mm Keypad Elastomer keypad; 3 function keys; OK key; 4 direction arrows; ON/OFF key; Escape key Material Housing and probe: ABS; Probe cable: neoprene; Plasturgy of detachable probe: PA 6.6 reinforced 10 % glass fiber Protection IP40 Communication Bluetooth® (optional) / USB Power supply / Battery life Li-Ion battery 6 V 1.5 A / 10 h in continuous operating Voltage of power supply: 100-240 VAC, 50/60 Hz Battery charging time 10 h Operating / storage temperature From +5 to +50 °C / From -20 to +50 °C. Altitude: from 0 to 2000 m Analyser menus Example of analysis DHW network temperature Handle Flue gas probe External water trap Built-in printer LCD screen Single connector for flue gas probe (TcK+gas sampling) and draft Fixing cone INSTRUMENT DESCRIPTION Overview Connections Thermocouples connections External probes connection (Pt100 temperature, CH4...) USB Power supply connection connection LED Flue gas connection P- pressure plug P+ pressure plug Differential pressure plug Keypad Button for LED Ambient CO checking Top view Bottom view Right side view Number of interchangeable sensors 2 ( long-life O2 and CO-H2) 3 ( long-life O2 , CO-H2 and NO) Scalable Yes: NO or CH4 Yes: CH4 Calibration certificate Yes Yes Transport bag Yes Yes Flue gas probe and its water trap Yes Yes Magnetic protective cover Yes Yes Differential pressure kit Yes Yes LIGAZ-2 software Database creation (customers, boilers, inspections) Inspections downloading and printing Synchronisation instrument / PC (customers, boilers, inspections) Analyser configuration LOGAZ-2: Software allowing database creation (customers, boilers and inspections), inspections downloading and printing, customisable procedure reports creation, inspection planning, on-site service contracts management (operator planning, customer care) and real-time measurements visualisation and recording SCOT: Ambient CO probe SCO2T: Ambient CO2 probe SPA 150SP: Ambient Pt100 probe SKCL 150: Thermocouple probe SCI: Ionisation current measurement probe SDFG: Gas leak detection probe (CH4 PS-180: Flue gas with interchangeable contact ) duct, 180 mm length, use up to 500 °C PS-300: Flue gas with interchangeable contact duct, 300 mm length PS-750: Flue gas with interchangeable contact duct in INCONEL, 750 mm length PS-1000: Flue gas with interchangeable
contact duct in INCONEL, 1000 mm length PMO: Opacity pump Supplied with 50 filters and a reference table KEG: Gas network tightness kit Allows connection to the KIGAZ MOBILE application Graphic visualisation Saving Exportation under CSV, XML, PDF format Reports sending by e-mail 

Komentar

Postingan populer dari blog ini

MUKTAMAR BLOGGER 2013 : KUMPUL MENDINGINKAN PIKIRAN

Cara Kalibrasi BB20 TROTEC Coating Thickness Measuring Instrument